SMART display module
Display of CAN J1939 parameters on analogue displays.
Note: Rshunt 0-100 Ohm.
Sensor outputs 4x 4-20mA
Output CAN bus values as 4-20mA currents
for connecting a PLC
Wiring diagram:
(3)PIN_A 4-20mA 0-10Bar oil pressure SPN100
(7)PIN_B 4-20mA 0-120°C KM-Temp SPN110
(2)PIN_C 4-20mA 0-700l FuelRate SPN183
(6)PIN_D 4-20mA 0-5000 IstUPM SPN190
(8)Terminal 15 +UB
(4)Terminal 31 GND
(1)CAN-Low
(5)CAN-High
You can find more information here: ehb SMARTmodul 04 display module | ehb electronics gmbh (ehb-electronics.de)